V Cone Flowmeter

The V-cone flowmeter is a new type of differential pressure flow measuring device with a pointed cone coaxially installed in the measuring tube as the throttling part. It is a new type of throttling device based on the measurement principle of the venturi tube and integrating the advantages of the classic venturi tube, annular orifice plate and wear-resistant orifice plate.

Key Benefits

Product Description

The V-Cone is a differential pressure type flow meter with a unique design that conditions the flow prior to measurement.

  • Differential pressure is created by a cone placed in the center of the pipe.
  • The cone is shaped so that it “flattens” the fluid velocity profile in the pipe, creating a more stable signal across wide flow downturns.
  • Flow rate is calculated by measuring the difference between the pressure upstream of the cone at the meter wall and the pressure downstream of the cone through its center.

Key feature:

  • The upstream and downstream straight pipes are required to be short: the shortest upstream straight pipe length is 3D, (3D is required for the downstream installation of the valve), the downstream straight. The shortest pipe length is less than or equal to 3D.
  • Accuracy: ±0.5%; repeatability is 0.1%; range ratio reaches 15:1.
  • Dirt resistant and low pressure loss.
  • It has the function of flow adjustment and mixing of fluids.
  • Low pressure loss width range
  • Signal stability
  • Measurable high temperature, high pressure medium, and can measurable gas-liquid two-phase medium (moisture)

Application Range

The V-Cone Flow Meter is an advanced differential pressure instrument, which is ideal for use with liquid, steam or gas media in rugged conditions where accuracy, low maintenance and cost are important. V-cone flowmeter can be measured including:

Edit Content

GET IN TOUCH WITH US

Please do not hesitate to contact us for more information or help with your application. Our flowmeter specialists will find a solution for you.

Technical Specification

#
Item Name
Parameter Values
1
Applicable medium
V-cone flowmeter sensors are widely used in fluid flow measurement in municipal, electric power, chemical, petrochemical, metallurgical, food processing and other industries, and are suitable for almost all gas and liquid media
2
Accuracy grade
±1.0% (the accuracy of the differential pressure flow transmitter should be higher than 0.2 grade, including 0.2 grade), (β: 0.45--0.85 when β<0.55, range ratio 4:1, accuracy grade: ≤0.30)
3
Repeatability
0.1%
4
Working pressure
0-40MPa (there are multiple pressure levels to choose from)
5
Working temperature
-40--850℃
6
Ambient temperature
-40--65℃
7
Requirements for installing straight pipe sections
front 0-3D straight pipes, rear 0-1D straight pipes
8
Wide range ratio
usually 10:1, select appropriate parameters to reach 50:1
9
Small loss
the same β value, the pressure loss is 1/3--1/5 of the orifice plate
10
Caliber
15mm--2000mm

Ordering Details

MOQ

Just need 1 pcs

Order Lead Time

5 pcs/3 days, 10 pcs/5 days, 50 pcs/10 days

Shipping Terms

Courier delivery, by sea, by air

Port of Loading

Qingao, Tianjin, Shanghai, Shenzhen

Terms of Payment

T/T, L/C, Paypal, Terms of Payment

Warranty Period

12 Months